Continuous Monitoring Method (Edexcel A Level Chemistry): Revision Note
Exam code: 9CHO
Continuous Monitoring Method
Continuous monitoring involves collecting experimental data throughout the course of a reaction to plot a concentration-time graph
Two of the most common ways to collect this data are by:
Measuring the volume / amount of gas evolved over time
Measuring the mass of reactants lost over time
Another alternative method involves the use of colorimetry:
The iodination of propanone
The iodination of propanone provides a suitable experiment in which the rate of reaction can be measured throughout the reaction by using a colorimeter
The reaction is carried out using a catalyst of dilute sulfuric acid
The iodine decolourises during the reaction as it turns into iodopropanone and hydrogen iodide:
CH3COCH3 + I2 → CH3COCH2I + HI
The colorimeter measures colour absorbance which is proportional to the concentration of the coloured species
Before the investigation begins it is necessary to measure the absorbance of a set of standard solutions of iodine and obtain a calibration curve
For example, here is a calibration curve for a transition metal ion that allows you to convert colorimeter readings into concentrations:

A calibration curve showing the relationship between colour absorbance and concentration
The colorimeter uses very small volumes of solutions, so four burettes can be filled with solutions of 0.02 mol dm-3 iodine, 1.0 mol dm-3 propanone and 1.0 mol dm-3 sulfuric acid and distilled water
By varying the volumes of solutions while maintaining a constant total volume with the use of distilled water, you can obtain a number of different concentrations
The solutions are measured into a small beaker, leaving the iodine in a separate beaker - this starts the reaction, so it can be added when you start a timer or stop watch
The iodine is added to the other liquids, the contents mixed and then quickly transferred into the cuvette (small receptacle) and the colorimeter / data logger started

The set up for using a colorimeter and data logger to continuously measure the rate of reaction
A typical set of volume compositions could be as follows:
Volume Compositions Table
Run | Iodine / cm3 | Sulfuric acid / cm3 | Water / cm3 | Propanone / cm3 |
|---|---|---|---|---|
1 | 4 | 1 | 4 | 1 |
2 | 4 | 1 | 3 | 2 |
3 | 4 | 1 | 2 | 3 |
4 | 4 | 1 | 1 | 4 |
5 | 4 | 1 | 0 | 5 |
Practical tip
Choose a filter that gives the strongest absorbance for the solution you are using - this will be the complementary colour to the colour of the solution under investigation
The specimen results below are for run 5, so the initial concentration of iodine is 0.0080 mol dm-3
Specimen results table for the iodination of propanone
Time / s | Concentration of iodine / mol dm-3 |
|---|---|
0 | 0.00800 |
60 | 0.00782 |
120 | 0.00764 |
180 | 0.00746 |
240 | 0.00728 |
300 | 0.00710 |
360 | 0.00692 |
420 | 0.00674 |
480 | 0.00656 |
540 | 0.00638 |
600 | 0.00620 |

Graph showing the change in concentration of iodine during the course of the reaction
Measuring rate
The rate of reaction is the gradient of the concentration-time graph
For a curve, a tangent is drawn at the time of interest and its gradient found
For the iodination of propanone the graph is a straight line, so the gradient, and therefore the rate, is constant: the reaction is zero order with respect to iodine
Gradient = Δy / Δx = (0.00620 - 0.00800) / 600 = -3.0 x 10-6 mol dm-3 s-1, so the rate of reaction is 3.0 x 10-6 mol dm-3 s-1
Examiner Tips and Tricks
Whichever rates experiments you carry out, make sure you can
describe the steps in the procedure
name all the apparatus used
draw data tables which include headings and units
draw graphs showing labels, units and best fit lines
determine an initial gradient or at any point in the curve
Unlock more, it's free!
Was this revision note helpful?
Build on this topic